4.2.1 Set Adapter Type
iPort iPort (#MIIC-201)
iPort/AI iPort/AI (#MIIC-202)
iPort/AFM iPort/AFM (#MIIC-203)
Variable Variable Clock (#MIIC-201-V)
The Adapter Type argument should be the first argument in the argument list as it
controls the availability of other arguments. If the Adapter Type is not specified, the
startup adapter selection screen will be presented.
4.2.2 Set RS-232 Communication Port
COM1 (Default)
COM2...COM20
Set the RS-232 communications port attached to the I
2
C adapter.
4.2.3 Set RS-232 Baud Rate
BAUD19200 (Default)
BAUD57600 (iPort/AFM ONLY)
BAUD115200 (iPort/AFM ONLY)
Set the RS-232 Baud Rate.
4.2.4 Set I
2
C Bus Clock Rate
CLOCK12.5K (iPort ONLY)
CLOCK23K (iPort/AFM ONLY)
CLOCK86K (iPort/AFM ONLY)
CLOCK100K (iPort, iPort/AI, iPort/AFM, Default)
CLOCK400K (iPort/AFM ONLY)
VCLOCK=nnnHz (Variable ONLY. nnn=451...57787)
Set the I
2
C Bus Clock Rate to the specified value. The defaults rate for the Variable
Clock the adapter is 451Hz. The Variable Clock adapter does not support all rates
within the specified range. The Message Center will adjust the specified rate to the
nearest available supported rate.
Page view 30